Wednesday 24 January 2018

12) SF/FTP CAT 7

SF/FTP CAT 7
CategorySF/FTP CAT7-4PJacket Physical
Properties
Before Aging ensileStrength(Mpa) ≥13.5
Test StandardISO/IEC11801、TIA/EIA-568-C.2Elongation(%)≥150
ConductorMaterialSolid-Bare CopperAging Period(℃×hrs)100℃×24h×7d
Nom.O.D.(mm)0.58Up+0.003After Aging Tensile Strength(Mpa)≥12.5
Down-0.003Elongation(%)≥125
InsulationMaterialHDPEColdbend(-20±2℃×4h) No visible cracks
Diameter1.350±0.05mmElectrical
Characteristics
(20℃)
Impedance(Ω) :
(1-100MHz)
(100-250MHz)
(250-600MHz) 

100±15Ω
100±18Ω
100±25Ω
ShieldAl FoilDrain wireYesDelay Shew(ns/100m)≤25
BraidTC Coverage 40%Rip-cordYesNVP74%
JacketThickness0.60±0.05mmCapacitance (nf/100m) max4.5
ExternalO.D.8.1±0.3mmPair to Ground Unbalance (pf/100m)max330
MaterialPVC/LSZHDC Resistance(Ω/100m) max9.5
ColorAccording to the requiresDC Resistance Unbalance(%)max2.0
PackingWooden Reel&CartonPallet
DimensionAccording to the requires----------
Packing length305m/500m±1.5m----------
Technical Performance(100M);
Frequency
(MHz)
RL
≥dB
ATT
(20℃)
NEXT
≥dB
ACR
≥dB
Frequency
(MHz)
PSNEXT
≥dB
ELFEXT
≥dB
PSELFEXT
≥dB
1.020.02.078.076.0
1.075.078.075.0
4.023.03.778.074.3
4.075.078.075.0
8.024.55.278.072.8
8.075.075.972.9
10.025.05.978.072.1
10.075.074.071.0
16.025.07.478.070.6
16.075.069.966.9
20.025.08.378.069.7
20.075.068.065.0
25.024.39.378.068.7
25.075.066.063.0
31.2523.610.478.067.6
31.2575.064.161.1
62.521.514.975.560.6
62.572.558.155.1
10020.119.072.453.4
10069.454.051.0
15018.923.669.846.2
15066.850.247.2
20018.027.567.940.4
20064.948.045.0
25017.331.066.435.4
25063.446.043.0
30017.334.265.231.0
30062.244.541.5
60017.350.160.710.6
60057.738.435.4