Wednesday 24 January 2018

11 ) F/FTP CAT 6A

F/FTP CAT 6A
CategoryF/FTP CAT6A-4PJacket Physical
Properties
Before Aging ensileStrength(Mpa) ≥13.5
Test StandardISO/IEC11801、TIA/EIA-568-C.2Elongation(%)≥150
ConductorMaterialSolid-Bare CopperAging Period(℃×hrs)100℃×24h×7d
Nom.O.D.(mm)0.56Up+0.003After Aging Tensile Strength(Mpa)≥12.5
Down-0.003Elongation(%)≥125
InsulationMaterialHDPEColdbend(-20±2℃×4h) No visible cracks
Diameter1.350±0.05mmElectrical
Characteristics
(20℃)
Impedance(Ω)100±15Ω
ShieldAl FoilDrain wireTC0.40mmDelay Shew(ns/100m)≤30
Rip-cordYes NVP74%
JacketThickness0.60±0.05mmCapacitance (nf/100m) max4.5
ExternalO.D.7.6±0.3mmPair to Ground Unbalance (pf/100m)max330
MaterialPVC/LSZHDC Resistance(Ω/100m) max9.38
ColorAccording to the requiresDC Resistance Unbalance(%)max2.0
PackingWooden Reel&CartonPallet
DimensionAccording to the requires----------
Packing length305m/500m±1.5m----------
Technical Performance(100M);
Frequency
(MHz)
RL
≥dB
ATT
(20℃)
NEXT
≥dB
PS NEXT
≥dB
ACR-F
≥dB
PS ACR-F
≥dB
PS ANEX
≥dB
PS AACR-F
≥dB
1.020.02.174.372.367.864.867.067.0
4.023.03.865.363.355.852.867.066.2
10.025.05.959.357.347.844.867.058.2
16.025.07.556.254.243.740.767.054.1
20.025.08.454.852.841.838.867.052.2
31.2523.610.551.949.937.934.967.048.3
62.521.515.047.445.431.928.965.642.3
10020.119.144.342.327.824.862.538.2
20018.027.639.837.821.818.858.032.2
25017.331.138.336.319.816.856.530.2
30016.834.337.135.118.315.355.328.7
50015.245.333.831.813.810.852.024.2

No comments: